{
  "docId": "019de511-6ba6-7222-a735-5d8b8f1417c9",
  "docSlug": "6a44fb0bd40c5ea00b1cf0cf59fa8d42",
  "documentTitle": "Advent | Investor Presentation Deck | 33 slides",
  "authorId": "advent",
  "authorName": "Advent",
  "documentKindSlug": "pitchdeck",
  "documentKindLabel": "Pitch deck",
  "sourceTypeSlug": "investor_relations",
  "sourceTypeLabel": "Investor relations",
  "presentationDate": "2021-09-01 00:00:00",
  "orientation": "landscape",
  "aspectRatio": 1.7777778,
  "pageNumber": 24,
  "pageCount": 33,
  "prevPage": 23,
  "nextPage": 25,
  "slideType": "product_demo",
  "function": "present_solution",
  "density": "dense",
  "nDataPoints": 1,
  "notes": "The slide uses an exploded view diagram to explain the technical architecture of the fuel cell stack.",
  "elementsJson": null,
  "metadataConfidence": 1,
  "imagePath": null,
  "slideHref": "/slides/019de511-6ba6-7222-a735-5d8b8f1417c9/24",
  "deckHref": "/decks/019de511-6ba6-7222-a735-5d8b8f1417c9",
  "deckJsonHref": "/decks/019de511-6ba6-7222-a735-5d8b8f1417c9.json",
  "deckAnchorHref": "/decks/019de511-6ba6-7222-a735-5d8b8f1417c9#slide-24",
  "components": [
    {
      "bbox": {
        "h": 0.5,
        "w": 0.45,
        "x": 0.05,
        "y": 0.15
      },
      "kind": "image",
      "text": "Exploded view of fuel cell stack components",
      "attrs": null,
      "subkind": "infographic",
      "toolName": null,
      "toolSlug": null,
      "confidence": null,
      "componentId": "037f81f8-8ca4-43ef-86f4-557939f03a33",
      "frameworkName": null,
      "frameworkSlug": null
    },
    {
      "bbox": {
        "h": 0.15,
        "w": 0.4,
        "x": 0.55,
        "y": 0.75
      },
      "kind": "list",
      "text": "Product Development Plan: Develop & Scale-up MEA Production in-house (U.S.-based), Partner/license production of other components",
      "attrs": null,
      "subkind": "bullet",
      "toolName": null,
      "toolSlug": null,
      "confidence": null,
      "componentId": "206d5faa-5991-4d43-83d8-1cfd62c64c1d",
      "frameworkName": null,
      "frameworkSlug": null
    },
    {
      "bbox": {
        "h": 0.15,
        "w": 0.3,
        "x": 0.55,
        "y": 0.55
      },
      "kind": "list",
      "text": "MEA Cost Targets: $80/kW at mass scale, Roll to Roll Manufacturing, Ultra-low Platinum technology",
      "attrs": null,
      "subkind": "bullet",
      "toolName": null,
      "toolSlug": null,
      "confidence": null,
      "componentId": "90ba2a0e-09c6-46f7-8767-74dde889b632",
      "frameworkName": null,
      "frameworkSlug": null
    },
    {
      "bbox": {
        "h": 0.3,
        "w": 0.4,
        "x": 0.55,
        "y": 0.15
      },
      "kind": "list",
      "text": "1. Lightweight Composite End Plate\n2. Current Collector\n3. High Performance Bipolar Plate (BIP) With Integral Thermal Management\n4. Anode Gas Diffusion Electrode (GDE)\n5. High Temperature Polymer Electrolyte Membrane (HT-PEM)\n6. Cathode Gas Diffusion Electrode\n7. Assembled HT-PEM Membrane Electrode Assembly (MEA)",
      "attrs": null,
      "subkind": "numbered",
      "toolName": null,
      "toolSlug": null,
      "confidence": null,
      "componentId": "dc38714e-10cb-4e75-bf0c-ac7ff3dc09b5",
      "frameworkName": null,
      "frameworkSlug": null
    },
    {
      "bbox": {
        "h": 0.2,
        "w": 0.45,
        "x": 0.06,
        "y": 0.7
      },
      "kind": "paragraph",
      "text": "The MEA is the \"heart\" of the Fuel Cell and it defines: What fuels can be used, efficiency, power density. The design parameters for the rest of the components, including the balance of plant. The Total Cost of Ownership of the fuel cell system",
      "attrs": null,
      "subkind": "paragraph",
      "toolName": null,
      "toolSlug": null,
      "confidence": null,
      "componentId": "020cb09d-5c6f-4a09-9fdd-b8328f71c59c",
      "frameworkName": null,
      "frameworkSlug": null
    },
    {
      "bbox": {
        "h": 0.05,
        "w": 0.5,
        "x": 0.07,
        "y": 0.06
      },
      "kind": "title",
      "text": "ADVENT INSIDE THE FUEL CELL STACK: MEA & MORE",
      "attrs": null,
      "subkind": "headline",
      "toolName": null,
      "toolSlug": null,
      "confidence": null,
      "componentId": "922627e5-a893-4fe7-95ae-24957540c06a",
      "frameworkName": null,
      "frameworkSlug": null
    }
  ],
  "metrics": [],
  "tools": [
    {
      "name": "List presentation",
      "slug": "list-presentation",
      "agent": null,
      "layer": "slide",
      "matchId": "6d30e5b5-1727-4339-927f-84c90a7bfc01",
      "evidence": "The slide contains a list/numbered component detailing the components of the fuel cell stack.",
      "confidence": 0.9
    }
  ],
  "frameworks": [],
  "arcBeats": [
    {
      "to": 26,
      "from": 21,
      "beatId": "ad974f85-5d8b-4d4b-bca4-5e349a365443",
      "arcName": "The Sparkline",
      "arcSlug": "sparkline",
      "beatName": "Evidence",
      "beatSlug": "evidence",
      "evidence": "The deck provides technical details and competitive analysis to support Advent's technology.",
      "position": 3,
      "confidence": 0.8,
      "parentBeatName": null,
      "parentBeatSlug": null
    }
  ],
  "loops": [],
  "imagePathAlt": null,
  "thumbSrc": null,
  "thumbSrcAlt": null,
  "locked": true
}