{
  "docId": "019de076-48c2-7315-bf77-72d2721572a4",
  "docSlug": "9ba2b11c98152a86fe4ad3555ff50f91",
  "documentTitle": "Immatics | Investor Presentation Deck | 75 slides",
  "authorId": "immatics",
  "authorName": "Immatics",
  "documentKindSlug": "pitchdeck",
  "documentKindLabel": "Pitch deck",
  "sourceTypeSlug": "investor_relations",
  "sourceTypeLabel": "Investor relations",
  "presentationDate": "2023-11-01 00:00:00",
  "orientation": "landscape",
  "aspectRatio": 1.7777778,
  "pageNumber": 49,
  "pageCount": 75,
  "prevPage": 48,
  "nextPage": 50,
  "slideType": "solution",
  "function": "present_solution",
  "density": "balanced",
  "nDataPoints": 12,
  "notes": "The slide uses a 3x4 grid of line charts to demonstrate the safety profile of the proprietary TCER format.",
  "elementsJson": null,
  "metadataConfidence": 1,
  "imagePath": null,
  "slideHref": "/slides/019de076-48c2-7315-bf77-72d2721572a4/49",
  "deckHref": "/decks/019de076-48c2-7315-bf77-72d2721572a4",
  "deckJsonHref": "/decks/019de076-48c2-7315-bf77-72d2721572a4.json",
  "deckAnchorHref": "/decks/019de076-48c2-7315-bf77-72d2721572a4#slide-49",
  "components": [
    {
      "bbox": {
        "h": 0.7,
        "w": 0.65,
        "x": 0.15,
        "y": 0.2
      },
      "kind": "chart",
      "text": "12-panel grid of cytokine release assays",
      "attrs": null,
      "subkind": "line",
      "toolName": null,
      "toolSlug": null,
      "confidence": null,
      "componentId": "a1d71618-1df4-4eb5-afc1-cf4b54e02b81",
      "frameworkName": null,
      "frameworkSlug": null
    },
    {
      "bbox": {
        "h": 0.1,
        "w": 0.2,
        "x": 0.78,
        "y": 0.82
      },
      "kind": "source-note",
      "text": "Whole blood cytokine release assay. N=3 HLA-A*02-positive donors. N=16 cytokines tested, 4 exemplary cytokines shown.",
      "attrs": null,
      "subkind": null,
      "toolName": null,
      "toolSlug": null,
      "confidence": null,
      "componentId": "83607329-f603-42da-89dc-e310960945f6",
      "frameworkName": null,
      "frameworkSlug": null
    },
    {
      "bbox": {
        "h": 0.04,
        "w": 0.8,
        "x": 0.04,
        "y": 0.12
      },
      "kind": "title",
      "text": "Reduced Target-Unrelated Recruiter-Mediated Cytokine Release using a Low-Affinity Recruiter",
      "attrs": null,
      "subkind": "action-title",
      "toolName": null,
      "toolSlug": null,
      "confidence": null,
      "componentId": "6685cea1-961d-4bf9-bd08-3b37b069e0b7",
      "frameworkName": null,
      "frameworkSlug": null
    },
    {
      "bbox": {
        "h": 0.05,
        "w": 0.6,
        "x": 0.04,
        "y": 0.06
      },
      "kind": "title",
      "text": "TCER® Format Is Designed for Optimized Efficacy and Safety",
      "attrs": null,
      "subkind": "headline",
      "toolName": null,
      "toolSlug": null,
      "confidence": null,
      "componentId": "82550792-c540-459c-a5e4-f0524bf7a481",
      "frameworkName": null,
      "frameworkSlug": null
    }
  ],
  "metrics": [],
  "tools": [],
  "frameworks": [],
  "arcBeats": [],
  "loops": [],
  "imagePathAlt": null,
  "thumbSrc": null,
  "thumbSrcAlt": null,
  "locked": true
}