  "notes": "The slide highlights the technological superiority of AcQMap's non-contact charge-density mapping over traditional contact mapping methods.",
  "elementsJson": [
    "paragraph",
    "screenshot",
    "footnote"
  ],
  "metadataConfidence": 0.9,
  "imagePath": null,
  "slideHref": "/slides/019dd923-622c-750b-8b98-17b017c6aac8/15",
  "deckHref": "/decks/019dd923-622c-750b-8b98-17b017c6aac8",
  "deckJsonHref": "/decks/019dd923-622c-750b-8b98-17b017c6aac8.json",
  "deckAnchorHref": "/decks/019dd923-622c-750b-8b98-17b017c6aac8#slide-15",
  "components": [
    {
      "bbox": null,
      "kind": "callout",
      "text": "This is completely different from the product of contact mapping, which is 4-10x lower resolution, only touches the endocardium at a few discrete sources, and can only take snapshots of the chamber one region at a time.",
      "attrs": null,
      "subkind": null,
      "toolName": "Visual emphasis",
      "toolSlug": "visual-emphasis",
      "confidence": null,
      "componentId": "019dd952-fb8f-761b-afcd-2d218115e5be",
      "frameworkName": null,
      "frameworkSlug": null
    },
    {
      "bbox": {
        "h": 0.35,
        "w": 0.56,
        "x": 0.22,
        "y": 0.16
      },
      "kind": "image",
      "text": "AcQMap catheter diagram showing electrodes and ultrasound transducers",
      "attrs": null,
      "subkind": "illustration",
      "toolName": null,
      "toolSlug": null,
      "confidence": null,
      "componentId": "eba71703-ab76-49c4-818e-728251fa9f6c",
      "frameworkName": null,
      "frameworkSlug": null
    },
    {
      "bbox": {
        "h": 0.12,
        "w": 0.78,
        "x": 0.11,
        "y": 0.71
      },
      "kind": "paragraph",
      "text": "In about 3 minutes, the result is not just an activation map but an activation recording that can play back the entire chamber's electrical conduction patterns, in ultra-high resolution, beat-by-beat.",
      "attrs": null,
      "subkind": "paragraph",
      "toolName": null,
      "toolSlug": null,
      "confidence": null,
      "componentId": "58bbf3b3-7659-48c0-9b9a-295f0c7ea2c0",
      "frameworkName": null,
      "frameworkSlug": null
    },
    {
      "bbox": {
        "h": 0.15,
        "w": 0.78,
        "x": 0.11,
        "y": 0.51
      },
      "kind": "paragraph",
      "text": "Using the fundamental laws of electrostatics, physicist Gunter Scharf derived a method to infer the charge densities across the endocardium from the electric field measurements of the catheter.",
      "attrs": null,
      "subkind": "paragraph",
      "toolName": null,
      "toolSlug": null,
      "confidence": null,
      "componentId": "7a5211a0-f086-47e0-b874-66ce7c91060b",
      "frameworkName": null,
      "frameworkSlug": null
    },
    {
      "bbox": null,
      "kind": "quote",
      "text": "Biosense Webster claims a 1mm ultra-high resolution for its CARTO 3 mapping catheter, but that's only at the exact point at which the catheter touches the endocardium, with the radius around that point interpolated. — Footnote 14",
      "attrs": null,
      "subkind": null,
      "toolName": "Authority citation",
      "toolSlug": "authority-citation",
      "confidence": null,
      "componentId": "019dd952-fb8f-761b-afcd-30a39cb1f0d5",
      "frameworkName": null,
      "frameworkSlug": null
    },
    {
      "bbox": {
        "h": 0.06,
        "w": 0.78,
        "x": 0.11,
        "y": 0.85
      },
      "kind": "source-note",
      "text": "14 Biosense Webster claims a 1mm ultra-high resolution for its CARTO 3 mapping catheter, but that's only at the exact point at which the catheter touches the endocardium.",
      "attrs": {
        "numbered": true
      },
      "subkind": null,
      "toolName": null,
      "toolSlug": null,
      "confidence": null,
      "componentId": "04433391-7ee0-412a-8093-d8cd5c6a026e",
      "frameworkName": null,
      "frameworkSlug": null
    },
    {
      "bbox": {
        "h": 0.05,
        "w": 0.56,
        "x": 0.22,
        "y": 0.44
      },
      "kind": "source-note",
      "text": "Source: Grace, A et al High-resolution noncontact charge-density mapping of endocardial activation",
      "attrs": null,
      "subkind": null,
      "toolName": null,
      "toolSlug": null,
      "confidence": null,
      "componentId": "b0b2650c-834e-4886-a755-d0bd11c3ff23",
      "frameworkName": null,
      "frameworkSlug": null
    }
  ],
  "metrics": [],
  "tools": [],
  "frameworks": [],
  "arcBeats": [],
  "loops": [],
  "imagePathAlt": null,
  "thumbSrc": null,
  "thumbSrcAlt": null,
  "locked": true
}