{
  "docId": "019dd923-622c-750b-8b98-17b017c6aac8",
  "docSlug": "384ff8288d23",
  "documentTitle": "Acutus Medical Inc. (AFIB)",
  "authorId": "53_Kerrisdale_Capital",
  "authorName": "Kerrisdale Capital",
  "documentKindSlug": "research-note",
  "documentKindLabel": "Research note",
  "sourceTypeSlug": "short_seller",
  "sourceTypeLabel": "Short seller",
  "presentationDate": "2021-07-01 00:00:00",
  "orientation": "portrait",
  "aspectRatio": 0.77272725,
  "pageNumber": 14,
  "pageCount": 29,
  "prevPage": 13,
  "nextPage": 15,
  "slideType": "problem_statement",
  "function": "diagnose_problem",
  "density": "dense",
  "nDataPoints": 2,
  "notes": "The slide is a text-heavy research note from Kerrisdale Capital critiquing current medical technology.",
  "elementsJson": [
    "paragraph"
  ],
  "metadataConfidence": 0.9,
  "imagePath": null,
  "slideHref": "/slides/019dd923-622c-750b-8b98-17b017c6aac8/14",
  "deckHref": "/decks/019dd923-622c-750b-8b98-17b017c6aac8",
  "deckJsonHref": "/decks/019dd923-622c-750b-8b98-17b017c6aac8.json",
  "deckAnchorHref": "/decks/019dd923-622c-750b-8b98-17b017c6aac8#slide-14",
  "components": [
    {
      "bbox": null,
      "kind": "callout",
      "text": "The limitations of contact mapping also make it incapable of mapping more than one arrhythmia at a time, which makes it ill-suited to treat SVTs such as atrial flutter or atrial tachycardia.",
      "attrs": null,
      "subkind": null,
      "toolName": "Visual emphasis",
      "toolSlug": "visual-emphasis",
      "confidence": null,
      "componentId": "019dd952-fb8f-761b-afcd-655e15459b9f",
      "frameworkName": null,
      "frameworkSlug": null
    },
    {
      "bbox": {
        "h": 0.11,
        "w": 0.78,
        "x": 0.11,
        "y": 0.14
      },
      "kind": "paragraph",
      "text": "Additionally, though modern 3D contact mapping catheters have multiple electrodes and are designed to touch the endocardium at multiple locations at once, the most precise data will come from the exact locations touched by the electrodes while the data in between is interpolated.",
      "attrs": null,
      "subkind": "paragraph",
      "toolName": null,
      "toolSlug": null,
      "confidence": null,
      "componentId": "1664cc7e-482e-4911-91b8-585690a4b071",
      "frameworkName": null,
      "frameworkSlug": null
    },
    {
      "bbox": {
        "h": 0.08,
        "w": 0.78,
        "x": 0.11,
        "y": 0.79
      },
      "kind": "paragraph",
      "text": "Acutus' AcQMap system, consisting of a catheter, console, and workstation, is designed not only to solve the problems posed by the inherent limitations of contact mapping, but also to advance the field’s understanding of the mechanisms of AF.",
      "attrs": null,
      "subkind": "paragraph",
      "toolName": null,
      "toolSlug": null,
      "confidence": null,
      "componentId": "1ecbe559-2a3f-4518-b5e6-ff397ec65040",
      "frameworkName": null,
      "frameworkSlug": null
    },
    {
      "bbox": {
        "h": 0.09,
        "w": 0.78,
        "x": 0.11,
        "y": 0.45
      },
      "kind": "paragraph",
      "text": "Aside from the distorted visualizations produced by contact mapping, maneuvering the mapping catheter through the endocardium to create an informative map takes time and skill. The most skilled EPs can do this in 10-15 minutes, but on average it takes as long as 20-40 minutes.",
      "attrs": null,
      "subkind": "paragraph",
      "toolName": null,
      "toolSlug": null,
      "confidence": null,
      "componentId": "68a59d9a-e794-4b94-aa57-b905b10405d5",
      "frameworkName": null,
      "frameworkSlug": null
    },
    {
      "bbox": {
        "h": 0.11,
        "w": 0.78,
        "x": 0.11,
        "y": 0.29
      },
      "kind": "paragraph",
      "text": "Another issue with contact mapping is the subjectivity of measurement: electrode size, spacing between electrodes, degree of contact with the tissue, and direction of contact with the tissue all impact the voltage measurement, further complicating effective interpretation.",
      "attrs": null,
      "subkind": "paragraph",
      "toolName": null,
      "toolSlug": null,
      "confidence": null,
      "componentId": "9b434e30-39a3-452f-8201-6e8662587a3a",
      "frameworkName": null,
      "frameworkSlug": null
    },
    {
      "bbox": {
        "h": 0.04,
        "w": 0.78,
        "x": 0.11,
        "y": 0.09
      },
      "kind": "paragraph",
      "text": "map is analogous to a panorama photo of an event composed of disjointed images that were separately photographed over too long an interval, when what’s needed is a video recording.",
      "attrs": null,
      "subkind": "paragraph",
      "toolName": null,
      "toolSlug": null,
      "confidence": null,
      "componentId": "c6a00ff7-74a3-4a0b-9b40-69c674868d41",
      "frameworkName": null,
      "frameworkSlug": null
    },
    {
      "bbox": {
        "h": 0.06,
        "w": 0.78,
        "x": 0.11,
        "y": 0.59
      },
      "kind": "paragraph",
      "text": "The limitations of contact mapping also make it incapable of mapping more than one arrhythmia at a time, which makes it ill-suited to help treat SVTs such as atrial flutter or atrial tachycardia.",
      "attrs": null,
      "subkind": "paragraph",
      "toolName": null,
      "toolSlug": null,
      "confidence": null,
      "componentId": "fc6f1790-260d-471e-a68d-61046d624276",
      "frameworkName": null,
      "frameworkSlug": null
    }
  ],
  "metrics": [],
  "tools": [],
  "frameworks": [],
  "arcBeats": [],
  "loops": [],
  "imagePathAlt": null,
  "thumbSrc": null,
  "thumbSrcAlt": null,
  "locked": true
}