  "docId": "019dd923-622b-71dc-a6dc-f627b2cd690f",
  "docSlug": "d5cf668f7ec6",
  "documentTitle": "BP plc (BP)",
  "authorId": "23_Bluebell_Capital",
  "authorName": "Giuseppe Bivona and Marco Taricco",
  "documentKindSlug": "shareholder-letter",
  "documentKindLabel": "Shareholder letter",
  "sourceTypeSlug": "activist_investor",
  "sourceTypeLabel": "Activist investor",
  "presentationDate": "2024-07-23 00:00:00",
  "orientation": "portrait",
  "aspectRatio": 0.70656973,
  "pageNumber": 11,
  "pageCount": 20,
  "prevPage": 10,
  "nextPage": 12,
  "slideType": "appendix_disclosure",
  "function": "preempt_rebuttal",
  "density": "overcrowded",
  "nDataPoints": 6,
  "notes": "The slide provides a technical defense of overplanting by referencing official UK policy and NREL degradation studies.",
  "elementsJson": [
    "paragraph",
    "footnote"
  ],
  "metadataConfidence": 0.95,
  "imagePath": null,
  "slideHref": "/slides/019dd923-622b-71dc-a6dc-f627b2cd690f/11",
  "deckHref": "/decks/019dd923-622b-71dc-a6dc-f627b2cd690f",
  "deckJsonHref": "/decks/019dd923-622b-71dc-a6dc-f627b2cd690f.json",
  "deckAnchorHref": "/decks/019dd923-622b-71dc-a6dc-f627b2cd690f#slide-11",
  "components": [
    {
      "bbox": null,
      "kind": "callout",
      "text": "Whereas the nameplate capacity of the facility exceeds the generator's grid connection, to account for degradation in panel efficiency over time (for modern panel 0.3-0.5% per year), \"overplanting\" should be neutral.",
      "attrs": null,
      "subkind": null,
      "toolName": "Visual emphasis",
      "toolSlug": "visual-emphasis",
      "confidence": null,
      "componentId": "019dd953-3f40-73bb-a5ff-13c8183950cc",
      "frameworkName": null,
      "frameworkSlug": null
    },
    {
      "bbox": {
        "h": 0.03,
        "w": 0.7,
        "x": 0.15,
        "y": 0.82
      },
      "kind": "disclaimer",
      "text": "12 https://assets.publishing.service.gov.uk/media/65a788996a5ec000d731aba/nps-renewable-energy-infrastructure-en3.pdf",
      "attrs": null,
      "subkind": null,
      "toolName": null,
      "toolSlug": null,
      "confidence": null,
      "componentId": "46389d24-2ac0-454b-8684-bf1b6e72a0a9",
      "frameworkName": null,
      "frameworkSlug": null
    },
    {
      "bbox": {
        "h": 0.04,
        "w": 0.7,
        "x": 0.15,
        "y": 0.86
      },
      "kind": "disclaimer",
      "text": "13 The presence of defective boron-oxygen complex in the wafer used during the manufacturing of PV cells is the main reason for LID.",
      "attrs": null,
      "subkind": null,
      "toolName": null,
      "toolSlug": null,
      "confidence": null,
      "componentId": "c7e8b4ac-000a-49ec-8830-e164ed525ffa",
      "frameworkName": null,
      "frameworkSlug": null
    },
    {
      "bbox": {
        "h": 0.06,
        "w": 0.7,
        "x": 0.15,
        "y": 0.39
      },
      "kind": "paragraph",
      "text": "On average, solar panels degrade at a rate of less than 1% each year. The solar panel manufacturer's warranty generally backs this up, guaranteeing 90% production in the first ten years and 80% by year 25 or 30.",
      "attrs": null,
      "subkind": "paragraph",
      "toolName": null,
      "toolSlug": null,
      "confidence": null,
      "componentId": "1ccb5365-1b9a-493d-804d-cfa53a174c9b",
      "frameworkName": null,
      "frameworkSlug": null
    },
    {
      "bbox": {
        "h": 0.06,
        "w": 0.7,
        "x": 0.15,
        "y": 0.09
      },
      "kind": "paragraph",
      "text": "\"Overplanting\" refers to the situation in which the installed generating capacity or nameplate capacity of the facility is larger than the generator's grid connection.",
      "attrs": null,
      "subkind": "paragraph",
      "toolName": null,
      "toolSlug": null,
      "confidence": null,
      "componentId": "48b1acc6-03a2-4118-bb5a-a7b39caabc1a",
      "frameworkName": null,
      "frameworkSlug": null
    },
    {
      "bbox": {
        "h": 0.06,
        "w": 0.7,
        "x": 0.15,
        "y": 0.46
      },
      "kind": "paragraph",
      "text": "A typical PV module is expected to degrade by 2% to 3% in its first year of operation... and 0.5% to 0.8% from year two of operation onward.",
      "attrs": null,
      "subkind": "paragraph",
      "toolName": null,
      "toolSlug": null,
      "confidence": null,
      "componentId": "7bff0e3f-6b86-4f38-b609-d2e36cda9d36",
      "frameworkName": null,
      "frameworkSlug": null
    },
    {
      "bbox": {
        "h": 0.05,
        "w": 0.7,
        "x": 0.15,
        "y": 0.53
      },
      "kind": "paragraph",
      "text": "According to a National Renewable Energy Laboratory (NREL) study... premium modern solar panel manufacturers such as Panasonic and LG offer panels with degradation rates as low as 0.30% per year.",
      "attrs": null,
      "subkind": "paragraph",
      "toolName": null,
      "toolSlug": null,
      "confidence": null,
      "componentId": "bb763559-f989-4a82-8e12-3823cf5cda7b",
      "frameworkName": null,
      "frameworkSlug": null
    },
    {
      "bbox": null,
      "kind": "quote",
      "text": "\"Overplanting\" refers to the situation in which the installed generating capacity or nameplate capacity of the facility is larger than the generator's grid connection. — National Policy Statement for Renewable Energy Infrastructure - EN-3, Appendix 6, p. 95",
      "attrs": null,
      "subkind": null,
      "toolName": "Authority citation",
      "toolSlug": "authority-citation",
      "confidence": null,
      "componentId": "019dd953-3f40-73bb-a5ff-15874e8d54c3",
      "frameworkName": null,
      "frameworkSlug": null
    },
    {
      "bbox": {
        "h": 0.02,
        "w": 0.25,
        "x": 0.58,
        "y": 0.04
      },
      "kind": "title",
      "text": "BLUEBELL CAPITAL PARTNERS",
      "attrs": null,
      "subkind": "headline",
      "toolName": null,
      "toolSlug": null,
      "confidence": null,
      "componentId": "2faafd0c-3df4-45b1-a5ad-f906e7e3fbcf",
      "frameworkName": null,
      "frameworkSlug": null
    }
  ],
  "metrics": [],
  "tools": [],
  "frameworks": [
    {
      "name": "preempt_rebuttal",
      "slug": null,
      "matchId": "68fb3f03-bc1b-43fc-b8c0-c55febe38b2d",
      "evidence": "The slide anticipates and refutes potential regulatory or technical objections to overplanting.",
      "confidence": 0.9
    }
  ],
  "arcBeats": [
    {
      "to": 13,
      "from": 11,
      "beatId": "35d0c5b1-354f-4879-b679-d8c96742dd64",
      "arcName": "Overcoming the Monster",
      "arcSlug": "overcoming-monster",
      "beatName": "The Call",
      "beatSlug": "overcoming-monster-the-call",
      "evidence": "The document issues a call to action, questioning the Board's decisions and demanding justification",
      "position": 2,
      "confidence": 0.8,
      "parentBeatName": "Complication",
      "parentBeatSlug": "complication"
    }
  ],
  "loops": [],
  "imagePathAlt": null,
  "thumbSrc": null,
  "thumbSrcAlt": null,
  "locked": true
}