{
  "docId": "019dd923-5de0-76bd-a167-fb14f4d30a04",
  "docSlug": "190510b49511442d",
  "documentTitle": "Lazard LCOE+",
  "authorId": "RolandBerger",
  "authorName": "Lazard",
  "documentKindSlug": "consulting-deck",
  "documentKindLabel": "Consulting deck",
  "sourceTypeSlug": "strategy_consulting",
  "sourceTypeLabel": "Strategy consulting",
  "presentationDate": null,
  "orientation": "landscape",
  "aspectRatio": 1.414,
  "pageNumber": 32,
  "pageCount": 48,
  "prevPage": 31,
  "nextPage": 33,
  "slideType": "appendix_data",
  "function": "analyze_data",
  "density": "dense",
  "nDataPoints": 40,
  "notes": "The chart breaks down LCOE into four distinct cost categories for different energy sources.",
  "elementsJson": [
    "bar_chart_stacked",
    "paragraph",
    "footnote"
  ],
  "metadataConfidence": 1,
  "imagePath": null,
  "slideHref": "/slides/019dd923-5de0-76bd-a167-fb14f4d30a04/32",
  "deckHref": "/decks/019dd923-5de0-76bd-a167-fb14f4d30a04",
  "deckJsonHref": "/decks/019dd923-5de0-76bd-a167-fb14f4d30a04.json",
  "deckAnchorHref": "/decks/019dd923-5de0-76bd-a167-fb14f4d30a04#slide-32",
  "components": [
    {
      "bbox": null,
      "kind": "callout",
      "text": "Certain renewable energy generation technologies are already cost-competitive with conventional generation technologies; key factors regarding the continued cost decline of renewable energy generation technologies are the ability of technological development and Industry scale to continue lowering operating expenses and capital costs for renewable energy generation technologies",
      "attrs": null,
      "subkind": null,
      "toolName": "Visual emphasis",
      "toolSlug": "visual-emphasis",
      "confidence": null,
      "componentId": "019dd951-dfa5-7563-a12d-cf9c0d44df6d",
      "frameworkName": null,
      "frameworkSlug": null
    },
    {
      "bbox": {
        "h": 0.55,
        "w": 0.91,
        "x": 0.045,
        "y": 0.31
      },
      "kind": "chart",
      "text": "Stacked bar chart showing LCOE components for 11 energy technologies",
      "attrs": null,
      "subkind": "bar-stacked",
      "toolName": null,
      "toolSlug": null,
      "confidence": null,
      "componentId": "94ca3699-0b9b-4b7b-877b-5c8fdc967c68",
      "frameworkName": null,
      "frameworkSlug": null
    },
    {
      "bbox": {
        "h": 0.03,
        "w": 0.4,
        "x": 0.045,
        "y": 0.92
      },
      "kind": "disclaimer",
      "text": "Source: Lazard and Roland Berger estimates and publicly available information. Notes: Figures may not sum due to rounding.",
      "attrs": null,
      "subkind": null,
      "toolName": null,
      "toolSlug": null,
      "confidence": null,
      "componentId": "53e10b45-9773-43e9-ab74-f65202c88a2d",
      "frameworkName": null,
      "frameworkSlug": null
    },
    {
      "bbox": {
        "h": 0.02,
        "w": 0.25,
        "x": 0.45,
        "y": 0.87
      },
      "kind": "legend",
      "text": "Capital Cost, Fixed O&M, Variable O&M, Fuel Cost",
      "attrs": null,
      "subkind": null,
      "toolName": null,
      "toolSlug": null,
      "confidence": null,
      "componentId": "0ea3d83d-2e4d-4705-a041-c356ea863ea4",
      "frameworkName": null,
      "frameworkSlug": null
    },
    {
      "bbox": null,
      "kind": "metric",
      "text": "LCOE ($/MWh): $142",
      "attrs": null,
      "subkind": "primary",
      "toolName": "Quantification",
      "toolSlug": "quantification",
      "confidence": null,
      "componentId": "019dd951-dfa5-7563-a12d-d386d84452ea",
      "frameworkName": null,
      "frameworkSlug": null
    },
    {
      "bbox": {
        "h": 0.07,
        "w": 0.91,
        "x": 0.045,
        "y": 0.215
      },
      "kind": "paragraph",
      "text": "Certain renewable energy generation technologies are already cost-competitive with conventional generation technologies; key factors regarding the continued cost decline of renewable energy generation technologies are the ability of technological development and Industry scale to continue lowering operating expenses and capital costs for renewable energy generation technologies",
      "attrs": null,
      "subkind": "paragraph",
      "toolName": null,
      "toolSlug": null,
      "confidence": null,
      "componentId": "367c004c-0cb2-4e79-91c5-5d98efe4babf",
      "frameworkName": null,
      "frameworkSlug": null
    },
    {
      "bbox": {
        "h": 0.025,
        "w": 0.42,
        "x": 0.045,
        "y": 0.158
      },
      "kind": "title",
      "text": "Levelized Cost of Energy Components—Low End",
      "attrs": null,
      "subkind": "headline",
      "toolName": null,
      "toolSlug": null,
      "confidence": null,
      "componentId": "d96cea68-7117-449e-a289-0d5c8337ae15",
      "frameworkName": null,
      "frameworkSlug": null
    }
  ],
  "metrics": [],
  "tools": [
    {
      "name": "Build-Up (Gradatio)",
      "slug": "build-up-gradatio",
      "agent": "Storyteller",
      "layer": "loop",
      "matchId": "019de8e9-c534-75ef-a7b5-c08fd4168634",
      "evidence": "Anchors loop 6: components build cumulatively to total LCOE",
      "confidence": 60
    },
    {
      "name": "Action Titles",
      "slug": "action-titles",
      "agent": "Architect",
      "layer": "slide",
      "matchId": "019de8e9-c4ae-77d1-ae5b-319ada17bfbf",
      "evidence": "Subhead states renewables 'already cost-competitive' driven by tech and scale",
      "confidence": 80
    },
    {
      "name": "Annotation",
      "slug": "annotation",
      "agent": "Designer",
      "layer": "slide",
      "matchId": "019de8e9-c4f2-777c-a454-84b136204d96",
      "evidence": "Per-segment dollar labels on each component",
      "confidence": 60
    },
    {
      "name": "Chart Selection Guide",
      "slug": "chart-selection-guide",
      "agent": "Designer",
      "layer": "slide",
      "matchId": "019de8e9-c4d0-75b9-898b-a5fa0871a217",
      "evidence": "Stacked horizontal bar chart for cost components",
      "confidence": 70
    },
    {
      "name": "Layering and Separation",
      "slug": "layering-and-separation",
      "agent": "Designer",
      "layer": "slide",
      "matchId": "019de8e9-c513-70ae-8ce7-393cf95dcee4",
      "evidence": "Stack separates Capital, Fixed O&M, Variable O&M, Fuel",
      "confidence": 80
    }
  ],
  "frameworks": [],
  "arcBeats": [
    {
      "to": 47,
      "from": 30,
      "beatId": "019de8e9-baaf-7498-afad-9147e9866acd",
      "arcName": "The Onion",
      "arcSlug": "onion",
      "beatName": "Core Insight",
      "beatSlug": null,
      "evidence": "Methodology and key-assumptions appendix",
      "position": 4,
      "confidence": 35,
      "parentBeatName": null,
      "parentBeatSlug": null
    }
  ],
  "loops": [
    {
      "to": 33,
      "from": 32,
      "name": "Build Up",
      "slug": "33-build-up",
      "bestFor": "Pricing justification, cost estimation, market sizing",
      "matchId": "019de8e9-bba1-778f-8574-555fdd765914",
      "evidence": "Stacked bars build cost from Capital + Fixed O&M + Variable O&M + Fuel for low-end (p.32) and high-end (p.33).",
      "position": 6,
      "objective": "Decompose LCOE into Capital, O&M, Fuel components",
      "structure": "The Base -> Add Component A -> Add Component B -> Add Component C -> The Total",
      "confidence": 65,
      "description": "Start from zero and add components to arrive at a total"
    }
  ],
  "imagePathAlt": null,
  "thumbSrc": null,
  "thumbSrcAlt": null,
  "locked": true
}